H600 V TurboMounting / Heavy-Duty Series
H600 V Turbo

H600 V Turbo

Our premium heating solutions will be listed here.

Specifications

Model
H600 V Turbo
H600 V Turbo
Electrical Data
Power (kVA)25
Voltage (V)380 – 420
Current (A)62.5
Frequency (Hz)50
Mechanical Data & Capacity
Heater Dimensions (W x D x H (mm))910 x 1150 x 1075 910 x 1150 x 2075 (With Crane)
Body MaterialSteel+Aluminum
Heater Weight (kg)380
Maximum Part Weight (kg)600
Maximum Part Diameter (mm)1200
Minimum Part Diameter (mm)43
Window Opening (H x W (mm))420 x 355
Heating Performance & Accessories
Magnetic temperature sensorK type
Turbo Heating
Turbo section min. diameter (mm)185
Standard Heating Bars (mm)60 x 60 x 700, 80 x 80 x 700, 100 x 100 x 700
Optional Heating Bars (mm)Please contact us.
Control & Interface
Heater control unitMicroprocessor
User interfaceCapacitive touch screen
Power selection steps10
Heating modesTime, Temperature, *Delta *: two sensors required
Time control (min)0-100
Temperature control (ºC)0-250
Safety & Functionality
Touch screen
ºF/ºC selection
Language option
Audio alert
Automatic demagnetization
Temperature hold function
Countdown function

Accessories

Heat Resistant Gloves

Heat Resistant Gloves

Carry Hot Parts Safely

Heat resistant gloves allow you to carry parts at temperatures up to 150°C (250°C with optional C250 gloves) safely and comfortably. By keeping user safety at the highest level, they provide maximum protection against hot parts. These gloves are included in the package of Fenixta bearing heaters and are also available for separate purchase. They can be used with bearing heaters from many brands such as FAG, SKF, and Betex, thus ensuring safe use with different devices.

Magnetic Temperature Sensor

Magnetic Temperature Sensor

Temperature Sensor Compatible with All Brand

The magnetic temperature sensor ensures precise and reliable measurements by firmly attaching to metal surfaces thanks to its powerful magnet. Capable of measuring up to 250°C, this sensor is included in the package of Fenixta bearing heaters and is also available for separate purchase. It can be used compatibly with bearing heaters from many brands such as FAG, SKF, and Betex.

Downloads

Device-specific quick start guides for fast setup.

FAQs

Bearing heaters operate on the principle of electromagnetic induction. Alternating current passing through coils inside the device creates a magnetic field. This magnetic field produces eddy currents on the bearing. These currents turn into heat due to the metal's own resistance, and the bearing heats up directly from within.

This method provides controlled and homogeneous heating without using open flames or ovens. Thus, the inner diameter of the bearing expands, allowing for installation without damaging the shaft.

⚠️

People with electronic devices, mechanical watches, and pacemakers should stay at least 1.5 meters away from the device.

For your safety, read the user manual. Danger of cardiac arrest for people with pacemakers due to the strong electromagnetic field! Serious burns can occur on hands as a result of touching hot material without protective gloves!

1. Connect the power cable to a suitable power source.

2. Turn the power switch to the ON position.

3. Place the bearing or workpiece. If it is large enough, put it in the turbo section. Make sure the yoke is positioned correctly.

4. Connect the temperature sensor to the socket on the device. Attach the magnetic sensor tip to the inner ring of the bearing.

5. Select the mode by touching the touch screen. Adjust the temperature, time, and power as needed.

6. Press the button or touch the screen to start heating.

7. When the heating process is complete, the device will give an audible warning.

8. Put on your gloves, remove the magnet and the yoke.

9. Place the bearing on the workpiece without wasting time.

Model selection depends on three basic criteria:

• Diameter of the bearing to be heated

• Weight of the bearing

• Frequency of the heating process

Additionally, power supply (220V / 380V), portability needs, and the workshop environment are decisive factors. Choosing the right capacity is important for energy efficiency and heating time. A device larger than necessary increases investment costs and works inefficiently with small bearings at the lower limit of capacity, while a small device leads to performance loss.

You can find the technical data of that product on the product pages. If you are still undecided, we are happy to help.

In induction systems, heat is generated directly within the bearing. Therefore, the body of the device does not heat up intensively. However, there may be heating in the core and some contact surfaces during operation.

Heating time depends on the size, weight of the bearing, and the target temperature. Small bearings can heat up in a few minutes, while in large and heavy bearings this time can take up to 15–20 minutes.

Induction systems provide much faster and more controlled results compared to traditional ovens or oil baths.

Of course. In addition to bearings, you can heat all closed-circuit conductors such as gears, pulleys, and rings in your device.

Compare

Loading...
Model
H10 Turbo
H10 Turbo
H35 Turbo
H35 Turbo
H125 Turbo
H125 Turbo
H300 Turbo
H300 Turbo
H600 Turbo
H600 Turbo
H600 V Turbo
H600 V Turbo
H1200 Turbo
H1200 Turbo
Electrical Data
Power (kVA)2.43.6612.4252540
Voltage (V)220 – 240220 - 240380 – 420380 – 420380 – 420380 – 420380 – 420
Current (A)1013153162.562.5100
Frequency (Hz)50505050505050
Mechanical Data & Capacity
Heater Dimensions (W x D x H (mm))315 x 205 x 260450 x 250 x 230550 x 250 x 365590 x 360 x 745 (Arms Closed) 1020 x 966 x 745 (Arms Open)790 x 460 x 910 (Arms Closed) 1170 x 1460 x 910 (Arms Open)910 x 1150 x 1075 910 x 1150 x 2075 (With Crane)1200 x 550 x 1100 (Arms Closed) 1500 x 1700 x 1100 (Arms Open)
Body MaterialAluminumAluminumAluminumSteel+AluminumSteel+AluminumSteel+AluminumSteel+Aluminum
Heater Weight (kg)102145144380380720
Maximum Part Weight (kg)10351253006006001200
Maximum Part Diameter (mm)210350500610120012001600
Minimum Part Diameter (mm)10102828434385
Window Opening (H x W (mm))140 x 69155 x 109218 x 156290 x 230420 x 355420 x 355650 x 500
Heating Performance & Accessories
Magnetic temperature sensorK typeK typeK typeK typeK typeK typeK type
Turbo Heating
Turbo section min. diameter (mm)84110122150185185235
Standard Heating Bars (mm)10 x 10 x 150, 20 x 20 x 150, 30 x 30 x 15014 x 14 x 225, 28 x 28 x 225, 45 x 45 x 22540 x 40 x 300, 60 x 60 x 30040 x 40 x 430, 60 x 60 x 430, 80 x 80 x 43060 x 60 x 700, 80 x 80 x 700, 100 x 100 x 70060 x 60 x 700, 80 x 80 x 700, 100 x 100 x 700150 x 150 x 850
Optional Heating Bars (mm)Please contact us.Please contact us.Please contact us.Please contact us.Please contact us.Please contact us.Please contact us.
Control & Interface
Heater control unitMicroprocessorMicroprocessorMicroprocessorMicroprocessorMicroprocessorMicroprocessorMicroprocessor
User interfaceCapacitive touch screenCapacitive touch screenCapacitive touch screenCapacitive touch screenCapacitive touch screenCapacitive touch screenCapacitive touch screen
Power selection steps10101010101010
Heating modesTime, Temperature, *Delta *: two sensors requiredTime, Temperature, *Delta *: two sensors requiredTime, Temperature, *Delta *: two sensors requiredTime, Temperature, *Delta *: two sensors requiredTime, Temperature, *Delta *: two sensors requiredTime, Temperature, *Delta *: two sensors requiredTime, Temperature, *Delta *: two sensors required
Time control (min)0 – 1000-1000-1000-1000-1000-1000 – 100
Temperature control (ºC)0 – 2500-2500-2500-2500-2500-2500 – 250
Safety & Functionality
Touch screen
ºF/ºC selection
Language option
Audio alert
Automatic demagnetization
Temperature hold function
Countdown function

Similar Products

H10 Turbo

H10 Turbo

Details
H35 Turbo

H35 Turbo

Details
H125 Turbo

H125 Turbo

Details