This carrying case is specially designed to safely carry the heating yokes that come with the Fenixta H35 Turbo bearing heater. It consists of three internal compartments made of tubular structure and two durable plastic covers, ensuring the bars remain safe and easy to access. The case includes a top handle for ergonomic use and can be custom-made for other Fenixta models upon request.
Accessories

Carrying Case
Easily Carry Your Device's Bars
This carrying case is specially designed to safely carry the heating yokes that come with the Fenixta H35 Turbo bearing heater. It consists of three internal compartments made of tubular structure and two durable plastic covers, ensuring the bars remain safe and easy to access. The case includes a top handle for ergonomic use and can be custom-made for other Fenixta models upon request.

Heating Bars (Yokes)
Heating Bars in Different Sizes
Fenixta bearing heating devices offer various heating bars (yokes) as standard in the box. Additional heating bars can be purchased separately to ensure the best heating performance and adapt to different bearing sizes. Production can be made with custom sizes and design options according to special needs; so you can order compatible bars for bearing heaters of many brands such as FAG, SKF, and Betex. This flexibility allows Fenixta products to offer a wide range of use.

Heat Resistant Gloves
Carry Hot Parts Safely
Heat resistant gloves allow you to carry parts at temperatures up to 150°C (250°C with optional C250 gloves) safely and comfortably. By keeping user safety at the highest level, they provide maximum protection against hot parts. These gloves are included in the package of Fenixta bearing heaters and are also available for separate purchase. They can be used with bearing heaters from many brands such as FAG, SKF, and Betex, thus ensuring safe use with different devices.

Magnetic Temperature Sensor
Temperature Sensor Compatible with All Brand
The magnetic temperature sensor ensures precise and reliable measurements by firmly attaching to metal surfaces thanks to its powerful magnet. Capable of measuring up to 250°C, this sensor is included in the package of Fenixta bearing heaters and is also available for separate purchase. It can be used compatibly with bearing heaters from many brands such as FAG, SKF, and Betex.
Accessories Table
| Code | Description |
|---|---|
| C150 | C150 150°C Heat resistant gloves (Standard) |
| C250 | C250 250°C Heat resistant gloves (Optional) |
| TS01 | TS01 250°C Temperature sensor |
| H35.C | H35.C H35 Turbo Carrying case |
Yoke Table
| Code | Model | Yoke dimensions | Minimum workpiece diameter | Rail system on yoke | Standard box contents |
|---|---|---|---|---|---|
| H10.L07 | H10 | 7mmx7mmx150mm | 10mm | - | - |
| H10.L10 | H10 | 10mmx10mmx150mm | 15mm | - | ✓ |
| H10.L20 | H10 | 20mmx20mmx150mm | 29mm | - | ✓ |
| H10.L30 | H10 | 30mmx30mmx150mm | 43mm | - | ✓ |
| H10.LX | H10 | (A)mmx(B)mmx150mm | Any size | - | - |
| H35.L10 | H35 | 10mmx10mmx225mm | 15mm | - | - |
| H35.L14 | H35 | 14mmx14mmx225mm | 20mm | - | ✓ |
| H35.L28 | H35 | 28mmx28mmx225mm | 40mm | - | ✓ |
| H35.L45 | H35 | 45mmx45mmx225mm | 64mm | - | ✓ |
| H35.LX | H35 | (A)mmx(B)mmx225mm | Any size | - | - |
| H125.L40 | H125 | 40mmx40mmx300mm | 57mm | ✓ | ✓ |
| H125.L60 | H125 | 60mmx60mmx300mm | 85mm | ✓ | ✓ |
| H125.LX | H125 | (A)mmx(B)mmx300mm | Any size | Special order | - |
| H300.L40 | H300 | 40mmx40mmx430mm | 57mm | ✓ | ✓ |
| H300.L60 | H300 | 60mmx60mmx430mm | 85mm | ✓ | ✓ |
| H300.L80 | H300 | 80mmx80mmx430mm | 114mm | ✓ | ✓ |
| H300.LX | H300 | (A)mmx(B)mmx430mm | Any size | Special order | - |
| H600.L60 | H600 | 60mmx60mmx700mm | 85mm | ✓ | ✓ |
| H600.L80 | H600 | 80mmx80mmx700mm | 114mm | ✓ | ✓ |
| H600.L100 | H600 | 100mmx100mmx700mm | 142mm | ✓ | ✓ |
| H600.LX | H600 | (A)mmx(B)mmx700mm | Any size | Special order | - |
| H600V.L60 | H600V | 60mmx60mmx700mm | 85mm | ✓ | ✓ |
| H600V.L80 | H600V | 80mmx80mmx700mm | 114mm | ✓ | ✓ |
| H600V.L100 | H600V | 100mmx100mmx700mm | 142mm | ✓ | ✓ |
| H600V.LX | H600V | (A)mmx(B)mmx700mm | Any size | Special order | - |
| H1200.L150 | H1200 | 150mmx150mmx850mm | 213mm | ✓ | ✓ |
| H1200.LX | H1200 | (A)mmx(B)mmx850mm | 213mm | Special order | - |
| Special order | xxx | Any size | Any size | - | - |
Downloads
Device-specific quick start guides for fast setup.
FAQs
Bearing heaters operate on the principle of electromagnetic induction. Alternating current passing through coils inside the device creates a magnetic field. This magnetic field produces eddy currents on the bearing. These currents turn into heat due to the metal's own resistance, and the bearing heats up directly from within.
This method provides controlled and homogeneous heating without using open flames or ovens. Thus, the inner diameter of the bearing expands, allowing for installation without damaging the shaft.
People with electronic devices, mechanical watches, and pacemakers should stay at least 1.5 meters away from the device.
For your safety, read the user manual. Danger of cardiac arrest for people with pacemakers due to the strong electromagnetic field! Serious burns can occur on hands as a result of touching hot material without protective gloves!
1. Connect the power cable to a suitable power source.
2. Turn the power switch to the ON position.
3. Place the bearing or workpiece. If it is large enough, put it in the turbo section. Make sure the yoke is positioned correctly.
4. Connect the temperature sensor to the socket on the device. Attach the magnetic sensor tip to the inner ring of the bearing.
5. Select the mode by touching the touch screen. Adjust the temperature, time, and power as needed.
6. Press the button or touch the screen to start heating.
7. When the heating process is complete, the device will give an audible warning.
8. Put on your gloves, remove the magnet and the yoke.
9. Place the bearing on the workpiece without wasting time.
Model selection depends on three basic criteria:
• Diameter of the bearing to be heated
• Weight of the bearing
• Frequency of the heating process
Additionally, power supply (220V / 380V), portability needs, and the workshop environment are decisive factors. Choosing the right capacity is important for energy efficiency and heating time. A device larger than necessary increases investment costs and works inefficiently with small bearings at the lower limit of capacity, while a small device leads to performance loss.
You can find the technical data of that product on the product pages. If you are still undecided, we are happy to help.
In induction systems, heat is generated directly within the bearing. Therefore, the body of the device does not heat up intensively. However, there may be heating in the core and some contact surfaces during operation.
Heating time depends on the size, weight of the bearing, and the target temperature. Small bearings can heat up in a few minutes, while in large and heavy bearings this time can take up to 15–20 minutes.
Induction systems provide much faster and more controlled results compared to traditional ovens or oil baths.
Of course. In addition to bearings, you can heat all closed-circuit conductors such as gears, pulleys, and rings in your device.
Compare
| Model | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
|---|---|---|---|---|---|---|---|
| Electrical Data | |||||||
| Power (kVA) | 2.4 | 3.6 | 6 | 12.4 | 25 | 25 | 40 |
| Voltage (V) | 220 – 240 | 220 - 240 | 380 – 420 | 380 – 420 | 380 – 420 | 380 – 420 | 380 – 420 |
| Current (A) | 10 | 13 | 15 | 31 | 62.5 | 62.5 | 100 |
| Frequency (Hz) | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Mechanical Data & Capacity | |||||||
| Heater Dimensions (W x D x H (mm)) | 315 x 205 x 260 | 450 x 250 x 230 | 550 x 250 x 365 | 590 x 360 x 745 (Arms Closed) 1020 x 966 x 745 (Arms Open) | 790 x 460 x 910 (Arms Closed) 1170 x 1460 x 910 (Arms Open) | 910 x 1150 x 1075 910 x 1150 x 2075 (With Crane) | 1200 x 550 x 1100 (Arms Closed) 1500 x 1700 x 1100 (Arms Open) |
| Body Material | Aluminum | Aluminum | Aluminum | Steel+Aluminum | Steel+Aluminum | Steel+Aluminum | Steel+Aluminum |
| Heater Weight (kg) | 10 | 21 | 45 | 144 | 380 | 380 | 720 |
| Maximum Part Weight (kg) | 10 | 35 | 125 | 300 | 600 | 600 | 1200 |
| Maximum Part Diameter (mm) | 210 | 350 | 500 | 610 | 1200 | 1200 | 1600 |
| Minimum Part Diameter (mm) | 10 | 10 | 28 | 28 | 43 | 43 | 85 |
| Window Opening (H x W (mm)) | 140 x 69 | 155 x 109 | 218 x 156 | 290 x 230 | 420 x 355 | 420 x 355 | 650 x 500 |
| Heating Performance & Accessories | |||||||
| Magnetic temperature sensor | K type | K type | K type | K type | K type | K type | K type |
| Turbo Heating | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Turbo section min. diameter (mm) | 84 | 110 | 122 | 150 | 185 | 185 | 235 |
| Standard Heating Bars (mm) | 10 x 10 x 150, 20 x 20 x 150, 30 x 30 x 150 | 14 x 14 x 225, 28 x 28 x 225, 45 x 45 x 225 | 40 x 40 x 300, 60 x 60 x 300 | 40 x 40 x 430, 60 x 60 x 430, 80 x 80 x 430 | 60 x 60 x 700, 80 x 80 x 700, 100 x 100 x 700 | 60 x 60 x 700, 80 x 80 x 700, 100 x 100 x 700 | 150 x 150 x 850 |
| Optional Heating Bars (mm) | Please contact us. | Please contact us. | Please contact us. | Please contact us. | Please contact us. | Please contact us. | Please contact us. |
| Control & Interface | |||||||
| Heater control unit | Microprocessor | Microprocessor | Microprocessor | Microprocessor | Microprocessor | Microprocessor | Microprocessor |
| User interface | Capacitive touch screen | Capacitive touch screen | Capacitive touch screen | Capacitive touch screen | Capacitive touch screen | Capacitive touch screen | Capacitive touch screen |
| Power selection steps | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Heating modes | Time, Temperature, *Delta *: two sensors required | Time, Temperature, *Delta *: two sensors required | Time, Temperature, *Delta *: two sensors required | Time, Temperature, *Delta *: two sensors required | Time, Temperature, *Delta *: two sensors required | Time, Temperature, *Delta *: two sensors required | Time, Temperature, *Delta *: two sensors required |
| Time control (min) | 0 – 100 | 0-100 | 0-100 | 0-100 | 0-100 | 0-100 | 0 – 100 |
| Temperature control (ºC) | 0 – 250 | 0-250 | 0-250 | 0-250 | 0-250 | 0-250 | 0 – 250 |
| Safety & Functionality | |||||||
| Touch screen | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| ºF/ºC selection | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Language option | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Audio alert | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Automatic demagnetization | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Temperature hold function | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Countdown function | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |